Browse by Category
Overview
Features
Specifications
Download
FAQ
Certification

1.Introduction
The GKA100 is a low cost and high performance RFID reader for reading ID code from uem4100 compatible read-only tags. The GKA100 reader features an extended reading range up to 3 feet. It is ideally suited to be applied in automatic parking system, personal identification, access control and production control systems etc.
2. Features
2. Features
High sensitivity and reliable performance;
Built-in transceiver antenna for maximum performance;
Maximum effective distance up to 3 feet;
Less than 100ms decoding time;
Low power dissipation with single power supply;
Multiple output format optional;
Built-in buzzer;
Built-in external LED control;
Potted for environmental protection.
3. Specifications
4. Interface
Power Requirements +12Volts DC @200mA typical, 250mA max.
Interface Wiegand or other optional
Typical Maximum Read Range Range 1000mm with ISO card (in ideal conditions)
Frequency 125KHz typical
Transponder Read Only
Audio/visual Indication Buzzer output with external LED control
4. Interface
|
Color
|
Description
|
|
Red
|
+12VDC
|
|
Black
|
GND
|
|
Green
|
DATA0
|
|
White
|
DATA1
|
|
Brown
|
HOLD
|
|
Yellow
|
External LED control(Internal 2K pulled-up)
|
5. Trouble Shooting
When powered up, the GKA100 take a self-test to ensure the best reading performance with the buzzer beeping continually. When the self-test ends, the buzzer will give out a long beep and the GKA100 enter the normal working mode. If the buzzer continue beeping without stop for a long time, please turn off the power and check out the environment and power supply to ensure locating the GKA100 in a good working condition. In case of problems the following procedure should be followed:
Failure to finish self-test with the buzzer beeping continually or with a short reading distance
1) Turn off the power to the GKA100;
2) Check the power input connections making sure that they are not reversed;
3) Check the power supply complying with the specification;
4) If the supply has a current limit, set this to 350mA;
5) Make sure to install the GKA100 in a environment without large area conductors nearby or mounting on a conductive surface. In self-test state, do not apply any tags in GKA100’s functional area;
6) Try to change the installment of the GKA100 to another place to check if the trouble still exists.